1,4-Benzenediol
Singlet oxygen


Mukai, K.; Itoh, S.; Daifuku, K.; Morimoto, H.; Inoue, K.
Biochim. Biophys. Acta 1183, 323-326 (1993)

Reaction: 1,4-C6H4(OH)2 + 1O2* ® products and/or physical quenching
Solvent: Ethanol

k = 1.4 × 107(L mol-1 s-1), T = 308K

Experimental method: Chemical reaction
Analytical method: vis-UV absorption
Data type: Derived from steady state measurements using indicator

Indicator = 1,3-Diphenylisobenzofuran; used solvent kd = 8.3 × 104 s-1; 1O2* from MNPO2.


Martire, D.O.; Braslavsky, S.E.; Garcia, N.A.
J. Photochem. Photobiol., A 61, 113-124 (1991)

Reaction: 1,4-C6H4(OH)2 + 1O2* ® products
Reference Reaction: 9,10-Dimethylanthracene + 1O2* ®
Solvent: Acetonitrile

kreact = 5 × 105(L mol-1 s-1), kreference = 1.3 × 108(L mol-1 s-1)

Experimental method: Photolysis
Analytical method: vis-UV emission
Data type: Relative value measured by steady state method

Photosensitizer = Mesoporphyrin IX, dimethyl ester.


Martire, D.O.; Braslavsky, S.E.; Garcia, N.A.
J. Photochem. Photobiol., A 61, 113-124 (1991)

Reaction: 1,4-C6H4(OH)2 + 1O2* ® products and/or physical quenching
Solvent: Acetonitrile

k = 2.8 × 107(L mol-1 s-1)

Experimental method: Flash photolysis
Analytical method: infrared luminescence
Data type: Absolute value measured directly

Photosensitizer = Rose Bengal dianion.


Martire, D.O.; Braslavsky, S.E.; Garcia, N.A.
J. Photochem. Photobiol., A 61, 113-124 (1991)

Reaction: 1,4-C6H4(OH)2 + 1O2* ® products and/or physical quenching
Solvent: D2O

k = 2.9 × 108(L mol-1 s-1)

Experimental method: Flash photolysis
Analytical method: infrared luminescence
Data type: Absolute value measured directly

Photosensitizer = Rose Bengal dianion.


Martire, D.O.; Braslavsky, S.E.; Garcia, N.A.
J. Photochem. Photobiol., A 61, 113-124 (1991)

Reaction: 1,4-C6H4(OH)2 + 1O2* ® products
Reference Reaction: DL-Histidine + 1O2* ®
Solvent: Water

kreact = 2.5 × 107(L mol-1 s-1), kreference = 7 × 107(L mol-1 s-1), T = 293K

Experimental method: Photolysis
Analytical method: oxygen consumption
Data type: Relative value measured by steady state method

Photosensitizer = Eosin dianion.


Tratnyek, P.G.; Hoigne, J.
Environ. Sci. Technol. 25, 1596-1604 (1991)

Reaction: 1,4-C6H4(OH)2 + 1O2* ® products
Reference Reaction: Furfuryl alcohol + 1O2* ®
Solvent: H2O

kreact ~ 4 × 107(L mol-1 s-1), kreference = 1.2 × 108(L mol-1 s-1), T = 300K

Experimental method: Modulated photolysis
Analytical method: HPLC
Data type: Relative value measured by steady state method

Photosensitizer = Rose Bengal dianion; reported k = (3.8 ± 5.5) × 107 L mol-1 s-1. [Indicator] = 5 × 10-5 (mol L-1).


Martire, D.O.; Braslavsky, S.E.; Garcia, N.A.
J. Photochem. Photobiol., A 61, 113-124 (1991)

Reaction: 1,4-C6H4(OH)2 + 1O2* ® products and/or physical quenching
Solvent: Dioxane

k = 1.9 × 107(L mol-1 s-1)

Experimental method: Flash photolysis
Analytical method: infrared luminescence
Data type: Absolute value measured directly

Photosensitizer = 5,10,15,20-Tetraphenylporphinatozinc(II).


Scurlock, R.; Rougee, M.; Bensasson, R.V.
Free Radical Res. Commun. 8, 251-258 (1990)

Reaction: 1,4-C6H4(OH)2 + 1O2* ® products and/or physical quenching
Solvent: CD3OD

k = 1.4 × 107(L mol-1 s-1), T = 293K

Experimental method: Flash photolysis
Analytical method: infrared luminescence
Data type: Absolute value measured directly
Excitation wavelength: 532 nm

Photosensitizer = Hematoporphyrin IX. [Indicator] = 5× 10-5-70 (mol L-1).


Slawinska, D.
Photochem. Photobiol. 28, 453-458 (1978)

Reaction: 1,4-C6H4(OH)2 + 1O2* ® products and/or physical quenching
Solvent: EtOH, 95%, H2O, 5%

k ~ 6 × 108(L mol-1 s-1)

Experimental method: Chemical reaction
Analytical method: infrared luminescence
Data type: Derived from steady state measurements

1O2* from pyrogallol autooxidation by O2/KOH; kd not given.


Fahrenholtz, S.R.; Doleiden, F.H.; Trozzolo, A.M.; Lamola, A.A.
Photochem. Photobiol. 20, 505-509 (1974)

Reaction: 1,4-C6H4(OH)2 + 1O2* ® products and/or physical quenching
Solvent: C5H5N

k = 6.9 × 107(L mol-1 s-1)

Experimental method: Modulated photolysis
Analytical method: vis-UV absorption
Data type: Derived from steady state measurements using indicator

Photosensitizer = Indicator = Rubrene; used solvent kd = 6.0 × 104 s-1; k for indicator = 4 × 107 L/(mol·s).


Foote, C.S.; Denny, R.W.; Weaver, L.; Chang, Y.; Peters, J.
Ann. N.Y. Acad. Sci. 171, 139-145 (1970)

Reaction: 1,4-C6H4(OH)2 + 1O2* ® products and/or physical quenching
Reference Reaction: 2-Methyl-2-pentene + 1O2* ®
Solvent: C6H6, 80%, MeOH, 20%

k = 7 × 107(L mol-1 s-1), bref = 4 × 10-2(mol L-1), kreference = 2.5 × 106(L mol-1 s-1), T = 298K

Experimental method: Photolysis
Analytical method: gas chromatography
Data type: Relative value measured by steady state method

Photosensitizer = Methylene Blue.


See also 4-(O)C6H4O
back...