Decay constant for singlet oxygen in the solvent: Acetone | ![]() |
Lifetime is 5.1 x 10–5 s
Decay rate is 2.0 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MB, TPP or PHO.
Lifetime is 5.4 x 10–5 s
Decay rate is 1.9 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is HVD and PPDME.
Lifetime is 3.8 x 10–5 s
Decay rate is 2.6 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is RB.
Lifetime is 4.3 x 10–5 s
Decay rate is 2.3 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is TPP.
Lifetime is 4.1 x 10–5 s
Decay rate is 2.4 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MB.
Lifetime is 4.6 x 10–5 s
Decay rate is 2.2 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is RB.
Lifetime is 4.8 x 10–5 s
Decay rate is 2.1 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is HP.
Decay rate is 2.0 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Ac.
Lifetime is 5.5 x 10–5 s
Decay rate is 1.8 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is An.
Lifetime is 4.7 x 10–5 s
Decay rate is 2.1 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is An.
Lifetime is 4.0 x 10–5 s
Decay rate is 2.5 x 104 s–1
Experimental method: pulsed laser photolysis, thermal buildup
Sensitizer is An.
Lifetime is 4.7 x 10–5 s
Decay rate is 2.1 x 104 s–1
Experimental method: pulsed laser photolysis, thermal buildup
Sensitizer is ZnTPP.
Lifetime is 5.0 x 10–5 s
Decay rate is 2.0 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is 2-ACN.
Lifetime is 2.5 x 10–5 s
Decay rate is 4.0 x 104 s–1
Experimental method: pulsed laser photolysis, thermal buildup
Sensitizer is Ery.
Lifetime is 3.0 x 10–5 s
Decay rate is 3.3 x 104 s–1
Experimental method: pulsed laser photolysis, thermal buildup
Sensitizer is TPP.
Lifetime is 5.0 x 10–5 s
Decay rate is 2.0 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is HPDME.
Lifetime is 4.7 x 10–5 s
Decay rate is 2.1 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MPDME
no change in k at T = 192 to 295 K.
Lifetime is 5.1 x 10–5 s
Decay rate is 2.0 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Sulfo- and carboxyanthracenes.
Lifetime is 4.6 x 10–5 s
Decay rate is 2.2 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MPDME.
Lifetime is 3.6 x 10–5 s
Decay rate is 2.8 x 104 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is An;
Substrate is DPBF.
Lifetime is 3.9 x 10–5 s
Decay rate is 2.6 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MB.
Lifetime is 4.0 x 10–5 s
Decay rate is 2.5 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is RB.
Lifetime is 5.1 x 10–5 s
Decay rate is 2.0 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is TPP.
Lifetime is 6.5 x 10–5 s
Decay rate is 1.5 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is HP.
Lifetime is 3.9 x 10–5 s
Decay rate is 2.6 x 104 s–1
Experimental method: continuous photolysis, luminescence intensity
Sensitizer is Benz[de]anthracen-7-one, phenalenone or fluorenone
rel. to kd = 4.0 x
104 s–1 in benzene.
Lifetime is 5.5 x 10–5 s
Decay rate is 1.8 x 104 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is 2-ACN;
Substrate is DPBF
cor. for kS.
Lifetime is 5.1 x 10–5 s
Decay rate is 2.0 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is PdMPDME.
Lifetime is 5.0 x 10–5 s
Decay rate is 2.0 x 104 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is TPP.
Lifetime is 4.2 x 10–5 s
Decay rate is 2.4 x 104 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is MB,
Substrate is DPBF.
Lifetime is 3 x 10–5 s
Decay rate is 4 x 104 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is MB,
Substrate is DPBF.