Decay constant for singlet oxygen in the solvent: Chloroform-d | ![]() |
Lifetime is 7.0 x 10–3 s
Decay rate is 1.4 x 102 s–1
Experimental method: modulated photolysis, luminescence decay
Sensitizer is MB, TPP or PHO
kd = 1.1 x 102 s–1
for [O2] <= 10–5 mol L–1.
Lifetime is 9.4 x 10–3 s
Decay rate is 1.1 x 102 s–1
Experimental method: modulated photolysis, luminescence decay
Sensitizer is TPP.
Lifetime is 6.4 x 10–4 s
Decay rate is 1.6 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is MB, RB or TPP.
Lifetime is 3.6 x 10–3 s
Decay rate is 2.8 x 102 s–1
Experimental method: continuous photolysis, luminescence intensity
Sensitizer is Benz[de]anthracen-7-one, phenalenone or fluorenone
rel. to kd = 4.0 x
104 s–1 in benzene.
Lifetime is 3.6 x 10–3 s
Decay rate is 2.8 x 102 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is Benz[de]anthracen-7-one, phenalenone or fluorenone.
Lifetime is 9 x 10–4 s
Decay rate is 1 x 103 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is 2-ACN;
Substrate is Rub
cor. for kS.
Lifetime is 8.4 x 10–4 s
Decay rate is 1.2 x 103 s–1
Experimental method: pulsed laser photolysis, luminescence decay
Sensitizer is PdMPDME.
Lifetime is 3 x 10–4 s
Decay rate is 3 x 103 s–1
Experimental method: pulsed laser photolysis, substrate disappearance
Sensitizer is MB,
Substrate is DPBF.