9-Acridinethione, 10-methyl- (NMTA)


Kumar, C.V.; Davis, H.F.; Das, P.K.
Chem. Phys. Lett. 109(2): 184-9 (1984)

Sensitizer: 9-Acridinethione, 10-methyl- (NMTA)
Solvent: c-C6H12
Oxygen concentration: O2

Fraction of T1 yielding singlet oxygen = 1

Experimental method: pulsed laser photolysis
Data type: time resolved substrate disappearance; sensitizer triplet absorbance at end-of-pulse

Singlet oxygen acceptor = DPBF; Triplet actinometer = S; meas. phiT(S) = 0.79; lambdaexc = 485 nm; used kd = 5.0 x 104 s-1, kA = 3.4 x 108 L mol-1 s-1, epsilonT(S) = 8800 L mol-1 cm-1 at 520 nm. Measured Proportion of T1 quenched by O2.


Kumar, C.V.; Davis, H.F.; Das, P.K.
Chem. Phys. Lett. 109(2): 184-9 (1984)

Sensitizer: 9-Acridinethione, 10-methyl- (NMTA)
Solvent: C6H6
Oxygen concentration: O2

Fraction of T1 yielding singlet oxygen = 0.92

Experimental method: pulsed laser photolysis
Data type: time resolved substrate disappearance; sensitizer triplet absorbance at end-of-pulse

Singlet oxygen acceptor = DPBF; Triplet actinometer = S; meas. phiT(S) = 0.85; lambdaexc = 485 nm; used kd = 4.0 x 104 s-1, kA = 8.0 x 108 L mol-1 s-1, epsilonT(S) = 9300 L mol-1 cm-1 at 520 nm. Measured Proportion of T1 quenched by O2.


Kumar, C.V.; Davis, H.F.; Das, P.K.
Chem. Phys. Lett. 109(2): 184-9 (1984)

Sensitizer: 9-Acridinethione, 10-methyl- (NMTA)
Solvent: CH3CN
Oxygen concentration: O2

Fraction of T1 yielding singlet oxygen = 0.85

Experimental method: pulsed laser photolysis
Data type: time resolved substrate disappearance; sensitizer triplet absorbance at end-of-pulse

Singlet oxygen acceptor = DPBF; Triplet actinometer = S; meas. phiT(S) = 0.76; lambdaexc = 485 nm; used kd = 2.5 x 104 s-1, kA = 1.0 x 109 L mol-1 s-1, epsilonT(S) = 9000 L mol-1 cm-1 at 520 nm. Measured Proportion of T1 quenched by O2.


Kumar, C.V.; Davis, H.F.; Das, P.K.
Chem. Phys. Lett. 109(2): 184-9 (1984)

Sensitizer: 9-Acridinethione, 10-methyl- (NMTA)
Solvent: MeOH
Oxygen concentration: O2

Fraction of T1 yielding singlet oxygen = 1.0

Experimental method: pulsed laser photolysis
Data type: time resolved substrate disappearance; sensitizer triplet absorbance at end-of-pulse

Singlet oxygen acceptor = DPBF; Triplet actinometer = S; meas. phiT(S) = 0.75; lambdaexc = 485 nm; used kd = 1.0 x 105 s-1, kA = 8.1 x 108 L mol-1 s-1, epsilonT(S) = 8500 L mol-1 cm-1 at 520 nm. Measured Proportion of T1 quenched by O2.


back...