UO22+

excited state quenched by Hg2+

Moriyasu, M.; Yokoyama, Y.; Ikeda, S.
J. Inorg. Nucl. Chem. 39: 2205-9 (1977)

UO22+ quenched by Hg2+
Solvent : H2O, 1 mol/L H3PO4, 25ºC

kq = 1.8 x 106(L mol–1 s–1)


Experimental methods: conventional flash, luminescence, , luminescence
Lifetime in the absence of quencher, air saturated = 180 micro sec.


Moriyasu, M.; Yokoyama, Y.; Ikeda, S.
J. Inorg. Nucl. Chem. 39: 2205-9 (1977)

UO22+ quenched by Hg2+
Solvent : H2O, 1 mol/L HClO4, 25ºC

kq = 8.2 x 106(L mol–1 s–1)


Experimental methods: conventional flash, luminescence, , luminescence
Lifetime in the absence of quencher, air saturated = 6.8 micro sec.


back...