Cr(4,7-Me2phen)33+excited state quenched by Fe2+ | ![]() |
Cr(4,7-Me2phen)33+ quenched by Fe2+
Solvent : H2O, 1 mol/L H2SO4, 25ºC
kq = 8.9 x 105(L mol–1 s–1)
Mechanism: reductive electron transfer
Experimental methods: steady state irradiation, luminescence
Lifetime in the absence of quencher, air free = 640 micro sec.
(laser flash, luminescence, multiple shot with signal averaging)
Cr(4,7-Me2phen)33+ quenched by Fe2+
Solvent : H2O, 1 mol/L HCl, 25ºC
kq = 6.0 x 106(L mol–1 s–1)
Mechanism: reductive electron transfer
Experimental methods: steady state irradiation, luminescence
Lifetime in the absence of quencher, air saturated = 37 micro sec.
(laser flash, luminescence, multiple shot with signal averaging)