Hydroxyl
Diamminesilver(I) ion


Kumar, A.; Neta, P.
J. Phys. Chem. 83, 3091-3095 (1979)

Reaction: ·OH + Ag(NH3)2+ ® Ag(NH3)2OH+
Solvent: H2O

k = 6 × 109(L mol-1 s-1)

Experimental method: Pulse radiolysis
Analytical method: vis-UV absorption
Data type: Absolute value measured directly

p.r.; No details given.