Hydroxyl
Cyanide ion


Bielski, B.H.J.; Allen, A.O.
J. Am. Chem. Soc. 99, 5931-5934 (1977)

Reaction: ·OH + CN- ® ·C(OH)=N-
Solvent: H2O

k = 8 × 109(L mol-1 s-1)

Experimental method: Pulse radiolysis
Analytical method: vis-UV absorption
Data type: Relative value measured directly

Competition kinetics; product hydrolyzes to ·CONH2 which disproportionates to formamide and cyanate; reference rate not given; rel. to k(·OH + Fe(CN)64-).


Buechler, Hch.; Buehler, R.E.; Cooper, R.
J. Phys. Chem. 80, 1549-1553 (1976)

Reaction: CN- + ·OH ® ·C(OH)=N-
Solvent: H2O

pH range 7.3 to 12
k = 7.1 × 109(L mol-1 s-1)

Experimental method: Pulse radiolysis
Analytical method: vis-UV absorption
Data type: Absolute value measured directly

Product buildup kinetics; product structure detd. by esr [72BEH/FES3].


Behar, D.
J. Phys. Chem. 78, 2660-2663 (1974)

Reaction: ·OH + CN- ® ·C(OH)=N-
Reference Reaction: ·OH + SCN- ®
Solvent: H2O

k/kreference = 6.9 × 10-1
k = 7.6 × 109(L mol-1 s-1), kreference = 1.1 × 1010(L mol-1 s-1), pH = 10.6

Experimental method: Pulse radiolysis
Analytical method: vis-UV absorption
Data type: Relative value measured directly

Competition kinetics (borate buffer); adduct protonates and rearranges to ·CONH2.


See also HCN
back...