Hydrated electron
| ![]() |
Anbar, M.; Hart, E.J.
J. Phys. Chem. 69, 973-977 (1965)
Reaction: eaq- + Ag(CN)2- ®
Solvent: H2O
k = 1.5 × 109(L mol-1 s-1), pH = 10
Experimental method: Pulse radiolysis
Analytical method: vis-UV absorption
Data type: Absolute value measured directly
Decay kinetics; counterion ClO4-; contains 0.1 mol L-1 CN-; cor. for matrix reaction.